logo
 
left right
shadow
OPTICAL UPRIGHT MICROSCOPE
 

TECHNICAL SPECIFICATION

In an upright microscope, the source of transmitted light and the condenser are located below the stage, pointing up. The objectives are placed on top of the stage, pointing down. The specimen is observed from the top through the lid of a petri dish or a coverslip.

Body - Trinocular Head inclined at 45°.

Focussing - Both side co-axial focussing knobs.

Nosepiece - Quadruple revolving nosepiece with accurate centering & positive click stops.

Stage - Large Co-axial Mechanical Stage for X-Y movement of specimens.

Illumination - Bright field vertical illuminator 6V-20W Halogen with field diaphragm, filter slots

and bulb centering mechanism.

Objectives - Achromatic DIN M4X-M10X & M40X.

Eyepieces - WF10X-H16X

Observation Method: Bright field

Objective/Nosepiece: Quadruple

Objective Magnification: 2.5x, 5x, 10x, 20X, 50x

Observation Tube Type: Binocular Tube

Light Filter: Blue

Eyepiece Magnification: With 10x magnification

Field of View: 20 mm

Viewing Head Inclination: 45 degree

Features of Optics/Lens: Polarizer & rotatable Analyser slider

Scanning Stage Type: Motorized - 2 axis Stage

Minimum X-Axis Travel Length (in mm): 75 millimeter

Minimum Y-Axis Travel Length (in mm): 40 millimeter

Minimum Z-Axis/Focus Travel Length (in mm): 10 millimeter

Accuracy of XY-Stage: +/-5 µm

Repeatability of XY-Stage: <2 µm

Resolution of XY-Stage: 0.1 μm

Resolution of Focus: <=10 nm

Accuracy of Focus: GOOD

Repeatability of Focus: GOOD

Motorized Stage Control: Through PC Software

Power Supply: 100 - 240 VAC, 50-60 Hz

Instruction manual will be provided along with the apparatus.


WEIGHING BALANCE
 

TECHNICAL SPECIFICATION

A weighing balance is a device that measures the weight or mass of an object. Weighing balances are used in laboratories, pharmacies, 

Capacity: 220g

Graphic display: coloured

Display size: 5.7 inch

Response time: 5 second

Weighing pan, mm: 40x40 or better

Eccentricity deviation (sd) (test load): 0.1mg (100g)

Capacity: 220g

Linearity deviation, mg: 0.2

Sensitivity offset, nominal load, mg: 0.01

Repeatability, mg: 0.01

Readability: 0.1mg/0.01mg

Operating temperature: 5 to <50 °c

Frequency (hertz): 50-60

Voltage (volt): 110-220

Display type: LCD

Instruction manual will be provided along with the apparatus.

 


ULTRASONIC PROBE SONICATOR
 

TECHNICAL SPECIFICATION

Probe Tip diameter: 3mm

Extra Titanium probe diameter in mm: 12-25

Variable processing time, range (second): 60

Variable probe tip amplitude range (in micron): 0.25

Weight: 4 kilogram

No. of replaceable tip included in the offer: 1

Additional Items: Titanium, probe, sound enclosure box

Working temperature range (in Deg. C): 35

Replaceable tip: Slots or flats cut over it

Power: 650 Watt

Variable Frequency (Khz): 25

Fixed Frequency (kHz): 20

Manual will be provided .


MAGNETIC STIRRERS
 TECHNICAL SPECIFICATION

Display: Digital

Minimum speed possible, RPM: 50

Magnetic Stirrer Type : Variable Speed

IP Rating: 42

Speed Control Accuracy of set speed (+/-) (RPM): 2

Maximum Stirring capacity per position: 2000 milliliter

Top plate material: Cast Aluminium

Base Material: Mild steel

User Interface: Digital front panel

Weight: 1.5 Kg

Permissible relative humidity, %: 50

Input Voltage with Phase (V): 220 V, 50 Hz AC, single phase

Input Current (A): 5

Power Consumption: 230 Watt

Speed Mode: Variable Speed

Speed (RPM): 1200

Minimum Speed increment step (RPM): 50

Maximum Speed (RPM) of variable speed mode equipment: 1200

External Dimension, Depth: 160 millimeter

External Dimension, Height: 30 millimeter

External Dimension, Width: 50 millimeter

Body Material: Metal Alloy

Finish of body material: Powder coated

Stir bar cover material: PTFE

Stir bar length: 1 millimeter

Top Plate Finish: Silicon coated Manual will be provided. 

ULTRASONIC CLEANERS
TECHNICAL SPECIFICATION

Heating capacity, Watt: 200

Power Supply, V: 220

Frequency, Hz: 50

Phase: Single phase

Tank capacity,(Litre): 11

Transducer (37-42 KHz): 200

Weight Kg: 14

Manual will be provided. 

Prev   177  178  179  180  181  182  183  184   Next
ULTRASONIC CLEANERS    MAGNETIC STIRRERS    ULTRASONIC PROBE SONICATOR    WEIGHING BALANCE    OPTICAL UPRIGHT MICROSCOPE    
Categories
  HIGHWAY ENGINEERING LAB
 ADVANCED COMMUNICATION LAB
 ANALYTICAL LAB EQUIPMENT
 APPLIED MECHANICS LAB
 AUTOMATION MANUFACTURING LAB
 BMCT
 CHEMICAL REACTION ENGINEERING LAB
 CIVIL ENGINEERING LAB
 CIVIL LAB ALL IN ONE
 CIVIL LAB EQUIPMENTS
 CONCRETE LAB
 CORE LAB
 ELECTRICAL ENGINEERNG LAB EQUIPMENTS
 ELECTRONICS ENGINEERING LAB EQUIPMENTS
 ELECTRONICS LAB
 ENVIRONMENT LAB
 ENVIRONMENTAL ENGINEERING LAB
 FLUID MACHINERY LAB
 FLUID MECHANICS LAB
 GEOLOGY LAB
 GEOTECHNICAL ENGINEERING LAB
 HEAT TRANSFER LAB
 HYDRAULIC BENCH & ACCESSORIES
 IC ENGINE LAB BL
 MANUFACTURING PROCESSES LAB
 MASS TRANSFER LAB
 MATERIAL TESTING & CONCRETE LAB
 MATERIAL TESTING LAB
 MATERIAL TESTING LAB
 MATERIAL TESTING LAB N
 MECHANICAL OPERATION LAB
 MEDICAL LAB EQUIPMENTS
 METALLURGICAL & MATERIAL SCIENCE LAB
 MOMENTUM TRANSFER LAB
 MONENTUM TRANSFER LAB
 MTL
 PETROLEUM TESTING LAB
 PHYSICS LAB
 PHYSICS LAB
 PROCESS CONTROL & INSTRUMENTATION LAB
 PRODUCTION LAB
 REFRIGERATION & AIR CONDITIONING LAB
 STEEL LAB RCC
 STRENGHT OF MATERIAL LAB
 STRUCTURE LAB
 SURVEY LAB
 SURVEYING & GEOMATICS LAB
 THEORY OF MACHINE LAB
 THERMODYNAMICS LAB
 TRANSPORTATION & HIGHWAY ENGINEERING LAB
 WORKSHOP
 
Follow us on
facebook twitter in  
 
bottom
 
Home About us Products Enquiry Contact us